All PRODUCT
-
Read More
Urological Stent (Double J Stent)
Advantage features:
Good flexibility and elasticity;
Large inner diameter, suitable pipe diameter, will not move up and down, X-ray can be developed;
Soft, high elasticity: tensile strength >15MPa, elongation at break >300%;
Processing range: 6F-18F
Services can be customized according to customer requirements -
Read More
Suction Catheter
Product Detail
Product advantages:
The single wall thickness is 0.05,
Divided into outer layer, inner layer and middle layer, each layer is made of different materials.
Outer Nylon, pebax, TPU specified mixture.
Inner PTFE, PFA, FEP, PEBAX, TPU.
Middle layer 304, NITI, Tungsten.
Variable PPI can be customized, weaving method is 1* 2,2 * 2,1 *1. The model is 1.7F-50F. -
Read More
Tungsten-filled Tube
Specializing in the manufacture of tungsten content up to 80% of the super development tube (optional materials TPU, Pebax, Nylon).
Traditional catheters are marked with gold or platinum rings for increased visibility during fluoroscopy. The purpose of tungsten tube is to develop, and tungsten, as a new alternative material, has a more significant advantage and can contain tungsten. Containing barium sulfate. Containing bismuth oxide. Containing bismuth trioxide and so on. Tungsten, through the innovative way of blending with thermoplastic materials, is smoother while maintaining the development effect. In addition, we offer hydrophilic coating services to bring out the best in your products. -
Read More
Vascular Access Sheath
The path was established, and the surface of the open pioneer sheath was smooth and had good folding resistance. Smooth tip design, not easy to damage blood vessels; It can support the guide wire and catheter through the long operation process
Disposable catheter sheath set
Rigid and flexible, Tongs wordless stainless steel spiral middle layer, enhance support; Whole body development, soft head end, protect blood vessels; Multi-end, multi-length diameter selection;
Processing capacity:
Unilateral wall thickness is the thinnest 0.05; Length 2800mm
Cover Nylon, pebax, TPU, specified mixture; Inner layer PTFE, PFA, FEP, PEBAX; Middle 304, NITI, Tungsten WPI as specified by customer. -
Read More
Multi-layer Composite Tube
Product Detail
The multi-layer composite pipe has excellent torsional control and flexural resistance, as well as good push off and smoothness.
Product composition
Inner layer:PTFE, PI, TPU, PA, PEBAX, PEEK, etc
Developing ring:Better visibility, more precise positioning, and safer operation
Mesh woven intermediate layer:
Stainless steel 304, NITI, Tungsten, etc
Weaving method: 1 * 1, 1 * 2, 2 * 2
Weaving the intermediate layer around the spring:
Stainless steel 304, NITI, Tungsten, etc
Weaving method: single/multiple wound springs, fixed density/variable density
Outer layer:Nylon, TPU, PEBAX, PEEK, etc
Support customization -
Read More
Multi-layer Co-extruded Tube
Can realize different raw materials, multi-layer composite co-extruded microcatheter. Our capabilities: Wall thickness 0.05-0.2mm -
Read More
Reusable Main Flexible Tube
These are primarily used in medical endoscopic equipment, industrial borescope inspection systems, or other applications that require high flexibility and reusability after sterilization. Their functions and features likely include:
Guiding endoscopic tools or lenses: Serves as the main conduit in endoscopic systems, allowing optical lenses, imaging cables, or micro surgical instruments to pass through.
Flexible design for easy bending: Suitable for navigating tight spaces inside the human body or mechanical equipment. -
Read More
Steerable Sheath
These are primarily used in medical endoscopic equipment, industrial borescope inspection systems, or other applications that require high flexibility and reusability after sterilization. Their functions and features likely include:
Guiding endoscopic tools or lenses: Serves as the main conduit in endoscopic systems, allowing optical lenses, imaging cables, or micro surgical instruments to pass through.
Flexible design for easy bending: Suitable for navigating tight spaces inside the human body or mechanical equipment. -
Read More
Working Channel Tube
It commonly used in medical endoscopic systems or industrial borescope inspection devices. Its main purposes include:
Instrument passage channel: Allows medical instruments (such as biopsy forceps, electrosurgical tools, injection needles, etc.) to pass through the tube and enter the body for diagnostic or therapeutic procedures.
Highly flexible metal structure: The spiral metal design provides excellent flexibility and pushability, ensuring smooth operation even in curved paths.
Durable and dimensionally stable: Designed for repeated use, maintaining a stable inner diameter to ensure instruments can pass through without obstruction.
Commonly used in flexible endoscopes (such as gastroscopes, colonoscopes): Acts as a critical component for therapeutic intervention. -
Read More
Working Channel
Product advantages:
Low friction coefficient
Excellent chemical resistance
Strong flexibility, high tensile strength
Withstand temperatures up to 260°C
Parameters:
PTFE extrusion WT0.02mm
PTFE dip coating WT0.005mm
Applicable to:
Cardiovascular intervention | endoscopy | neurosurgery -
Read More
Disposable Gastroscope Insertion Tube
Multi stage hardness differentiation, multi-layer reinforced structure, Smooth surface.
Three layer composite braided tube cavity structure
The inner layer is made of spring winding technology
The middle is the weaving process
The outer layer is made of materials such as PEBAX, PA, TPU, PVC, etc -
Read More
Disposable Main Flexible Tube
Ventilator Tubing: Connects patients to respiratory systems to deliver oxygen or air.
Suction or Drainage Tubes: Used for removing fluids during surgery or inpatient care.
Anesthesia Equipment: Transfers anesthetic gases to patients.